You are here : Home | Products & Systems | Reverse Osmosis | Herco RangeAntiscalant Dosing | Series AS / FU | ASFU 3800


 

Reverse Osmosis – Model ASFU 3800

As Series 2 Reverse Osmosis

Reverse Osmosis – Model ASFU 3800

AS / FU Series: 3800 – 8000 l/h Antiscalant-based Low Pressure RO systems. Low energy consumption with frequency controlled pump (AS/FU): savings potential up to 30% Low pressure systems for desalination of hardness stabilised drinking water (by antiscalant dosing) with a salt content of < 1000 mg/l. With RO 1000 and horizontal 8“ modules.

AS- and AS/FU-systems already contain: Control for metering pump Dosin AS-K Concentrate flushing device KSE Preparation for injection point Connection Set for manual cleaning unit, ARA


Tech DataUOAS 3800
Permeate flow ratel/h3800
Min. salt rejection%97
Recovery%75
Operating pressurebar12.0
Membrane element / number8040 / 3
VoltageV/Hz3 x 400/50
Motor powerkW5.5
Pre-fusingA16
Feedwater connectionDN32
Permeate/concentrate connectionDN32 / 32
Dosing point connectionR½"
Conductivity rangeμS/cm2 – 200
Heightmm1,900
Widthmm2,800
Depthmm750
Weight approxkg450
Code no.381 547