You are here : Home | Products & Systems | Reverse Osmosis | Herco Range | Antiscalant Dosing | BW BWFU | BWFU 5500
Reverse Osmosis – Model BWFUÂ 5500
Reverse Osmosis – Model BWFUÂ 5500
BW & BW/FU Series: 3500 – 6500 l/h Brackish water RO systems. Low energy consumption with frequency controlled pump (BW/FU): savings potential up to 30% Brackish water RO system for desalination of hardness stabilised drinking water (by anti-scalant dosing) with a salt content of up to 5000 mg/l. With RO 1000 microprocessor control system.
BW- and BW/FU-systems contain: Control for metering pump. Dosing AS-K Concentrate flushing device. KSE Preparation for injection point. Connection Set for manual cleaning.
Tech Data | UO | 5500 BW |
Permeate flow rate | l/h | 5500 |
Min. salt rejection | % | 97 |
Recovery | % | 50 |
Operating pressure | bar | 15 |
Membrane element / number | 8040 / 5 | |
Voltage | V/Hz | 3x400/50 |
Motor power | kW | 7.5 |
Pre-fusing | A | 20 |
Feedwater connection | DN | 50 |
Permeate/concentrate connection | DN | 40 / 40 |
Connection dosing point | R | ½" |
Conductivity range | μS/cm | 20 – 2,000 |
Height | mm | 1,900 |
Width | mm | 3,800 |
Depth | mm | 750 |
Weight approx | kg | 630 |
Code no. | 384 617 |