You are here : Home | Products & Systems | Reverse Osmosis | Herco Range | Soft Water Feed | Series WS & W | WS


 

Reverse Osmosis  Series WS

[one_third padding=”0 6px 0 0″]

Reverse Osmosis | WS Series | 100

[su_button url=”https://www.industrialwaterequipment.co.uk/reverse-osmosis-ws100/” background=”#f1f1f1″ color=”#33577a” size=”7″ wide=”yes” center=”yes” radius=”10″ icon_color=”#bebebe” text_shadow=”0px 0px 0px #676867″]WS 100[/su_button][/one_third]

[one_third padding=”0 6px 0 0″]

Reverse Osmosis | WS Series | 250

[su_button url=”https://www.industrialwaterequipment.co.uk/reverse-osmosis-ws250/” background=”#f1f1f1″ color=”#33577a” size=”7″ wide=”yes” center=”yes” radius=”10″ icon_color=”#bebebe” text_shadow=”0px 0px 0px #676867″]WS 250[/su_button][/one_third]

[one_third_last padding=”0 6px 0 0″]

Reverse Osmosis | WS Series | 300

[su_button url=”https://www.industrialwaterequipment.co.uk/reverse-osmosis-ws300/” background=”#f1f1f1″ color=”#33577a” size=”7″ wide=”yes” center=”yes” radius=”10″ icon_color=”#bebebe” text_shadow=”0px 0px 0px #676867″]WS 300[/su_button][/one_third_last]

[one_third padding=”0 6px 0 0″]

Reverse Osmosis | WS Series | 400

[su_button url=”https://www.industrialwaterequipment.co.uk/reverse-osmosis-ws400/” background=”#f1f1f1″ color=”#33577a” size=”7″ wide=”yes” center=”yes” radius=”10″ icon_color=”#bebebe” text_shadow=”0px 0px 0px #676867″]WS 400[/su_button][/one_third]

[one_third padding=”0 6px 0 0″]

Reverse Osmosis | WS Series | 500

[su_button url=”https://www.industrialwaterequipment.co.uk/reverse-osmosis-ws500/” background=”#f1f1f1″ color=”#33577a” size=”7″ wide=”yes” center=”yes” radius=”10″ icon_color=”#bebebe” text_shadow=”0px 0px 0px #676867″]WS 500[/su_button][/one_third]

[one_third_last padding=”0 6px 0 0″][/one_third_last]

[su_spacer size=”30″][su_spacer][/su_spacer]

Reverse Osmosis – WS Series

W/S Series: 100 – 500 l/h Wall mounting / stand-type RO unit. For desalination of softened drinking water according to German drinking water regulations (free chlorine not detectable), operating on the principle of reverse osmosis. Drinking water can also be desalinated without pre-treatment. However, in this case the recovery rate is reduced. The decisive factor is the water analysis.

Stainless steel base frame suitable for mounting on the wall or floor.
Special inlet filter with 5 μm-filter cartridge high pressure pump, rotary-vane type, high performance wound module with PA/PS composite membranes in GRP pressure vessel with inliner.


[su_note note_color=”#f4f4f4″]WS Series Specification[/su_note]

Description

Stainless steel base frame suitable for mounting on the wall or floor.
Special inlet filter with 5 μm-filter cartridge high pressure pump, rotary-vane type, high performance wound module with PA/PS composite membranes in GRP pressure vessel with inliner. Valves and instruments including solenoid inlet valve, feedwater pressure switch, permeate and concentrate flow meter, vibration-resistant pressure gauge for pump pressure, valves for adjustment of permeate and concentrate flow rate and concentrate recirculation. Microprocessor control system as described below, connecting cable (3 m) with 16 A – 6 h CEE three-pole plug. Unit completely wired and pre-assembled and ready for installation. Electrical equipment in accordance with VDE 0100 part 600, VDE 113 part 1

RO 500 microprocessor control system

for fully automated monitoring and control of the reverse osmosis unit with two-digit alphanumeric display of permeate conductivity, forced stop and full tank, malfunction signals: low pressure, hard water and high conductivity, LEDs for operation and disinfection, inputs (low voltage) for level control with 1 or 2 float switches, hardness monitoring unit (the RO 500 controller includes control functions for the limitron hardness monitoring unit), shut-downs by external signal (forced stop, regeneration), outputs for softening unit (230 V / 50 Hz) and DDC (collective malfunction signal on floating changeover contact). The units are designed for a maximum TDS of 1,000 mg/l, a water temperature of 15°C, a maximum colloidal index of 3 and free permeate outlet. Under these conditions, the units sill reach design permeate flow after three years of operation. With new units the working pressure is about 15 % lower. The permeate recovery depends on the raw water quality and the type of pre-treatment.