You are here : Home | Consumables | Reverse Osmosis Membranes | Hydranautics | HYDRAcap

HYDRAcap is used to treat surface water, ground water, seawater and waste water as either primary treatment or as pretreament to reverse osmosis (RO) and nanofiltration (NF).
[su_spacer size=”30″]HYDRAcap 40 – 40″
| Configuration | Capillary Ultrafiltration Module |
| Membrane Polymer | Hydrophillic Polyethersulfone |
| Typical Filtrate Flux Range | 35 - 85 gfd (59 - 145 l/m2/h) |
| Maximum Applied Feed Pressure | 73 psig (5bar) |
| Maximum Transmenbrane Pressure | 20 psig (1.4 bar) |
| Maximum Backwash Transmenbrane Pressure | 20 psig (1.4 bar) |
| Instantaneous Chlorine Tolerence | 100 ppm |
| Instantaneous Hydrogen Peroxide Tolerence | 200 ppm |
| Maximum Chlorine Exposure | 200,000 ppm-hrs |
| Maximum Instantaneous Feed Turbidity | 100 NTU |
| Maximum Operating Temperature | 104ºF (40ºC) |
| pH Operating Range | 4.0 - 10.0 |
| Cleaning pH Range | 1.5 - 13.0 |
| Operating Mode | Inside to Outside filtration Direct flow or crossflow |
HYDRAcap 40 LD – 40″
| Configuration | Capillary Ultrafiltration Module |
| Membrane Polymer | Hydrophillic Polyethersulfone |
| Typical Filtrate Flux Range | 35 - 85 gfd (59 - 145 l/m2/h) |
| Maximum Applied Feed Pressure | 73 psig (5bar) |
| Maximum Transmenbrane Pressure | 20 psig (1.4 bar) |
| Maximum Backwash Transmenbrane Pressure | 20 psig (1.4 bar) |
| Instantaneous Chlorine Tolerence | 100 ppm |
| Instantaneous Hydrogen Peroxide Tolerence | 200 ppm |
| Maximum Chlorine Exposure | 200,000 ppm-hrs |
| Maximum Instantaneous Feed Turbidity | 200 NTU |
| Maximum Operating Temperature | 104ºF (40ºC) |
| pH Operating Range | 4.0 - 10.0 |
| Cleaning pH Range | 1.5 - 13.0 |
| Operating Mode | Inside to Outside filtration Direct flow or crossflow |
HYDRAcap MAX 40 – 40″
| Configuration | Capillary Microfiltration Module |
| Membrane Polymer | PVDF |
| Typical Filtrate Flux Range | 20 - 65 gfd (34 - 110 l/m2/h) |
| Maximum Applied Feed Pressure | 73 psig (5bar) |
| Maximum Transmenbrane Pressure | 30 psig (2.0 bar) |
| Maximum Backwash Transmenbrane Pressure | |
| Instantaneous Chlorine Tolerence | 5000 ppm |
| Instantaneous Hydrogen Peroxide Tolerence | |
| Maximum Chlorine Exposure | 750,000 ppm-hrs |
| Maximum Instantaneous Feed Turbidity | 300 NTU |
| Maximum Operating Temperature | 104ºF (40ºC) |
| pH Operating Range | 4.0 - 10.0 |
| Cleaning pH Range | 1.0 - 13.0 |
| Operating Mode | Inside to Outside filtration Dead end or crossflow mode |
HYDRAcap 60 – 60″
| Configuration | Capillary Ultrafiltration Module |
| Membrane Polymer | Hydrophilic Polyethersulphone |
| Typical Filtrate Flux Range | 35 - 85 gfd (59 - 145 l/m2/h) |
| Maximum Applied Feed Pressure | 73 psig (5bar) |
| Maximum Transmenbrane Pressure | 20 psig (1.4 bar) |
| Maximum Backwash Transmenbrane Pressure | 20 psig (1.4 bar) |
| Instantaneous Chlorine Tolerence | 100 ppm |
| Instantaneous Hydrogen Peroxide Tolerence | 200 ppm |
| Maximum Chlorine Exposure | 200,000 ppm-hrs |
| Maximum Instantaneous Feed Turbidity | 100 NTU |
| Maximum Operating Temperature | 104ºF (40ºC) |
| pH Operating Range | 4.0 - 10.0 |
| Cleaning pH Range | 1.0 - 13.0 |
| Operating Mode | Inside to Outside filtration Direct Flow or crossflow mode |
HYDRAcap 60 LD – 60″
| Configuration | Capillary Ultrafiltration Module |
| Membrane Polymer | Hydrophilic Polyethersulphone |
| Typical Filtrate Flux Range | 35 - 85 gfd (59 - 145 l/m2/h) |
| Maximum Applied Feed Pressure | 73 psig (5bar) |
| Maximum Transmenbrane Pressure | 20 psig (1.4 bar) |
| Maximum Backwash Transmenbrane Pressure | 20 psig (1.4 bar) |
| Instantaneous Chlorine Tolerence | 100 ppm |
| Instantaneous Hydrogen Peroxide Tolerence | 200 ppm |
| Maximum Chlorine Exposure | 100,000 ppm-hrs |
| Maximum Instantaneous Feed Turbidity | 200 NTU |
| Maximum Operating Temperature | 104ºF (40ºC) |
| pH Operating Range | 4.0 - 10.0 |
| Cleaning pH Range | 1.5 - 13.0 |
| Operating Mode | Inside to Outside filtration Direct Flow or crossflow mode |
HYDRAcap MAX 60 – 60″
| Configuration | Capillary Ultrafiltration Module |
| Membrane Polymer | Hydrophilic Polyethersulphone |
| Typical Filtrate Flux Range | 35 - 85 gfd (59 - 145 l/m2/h) |
| Maximum Applied Feed Pressure | 73 psig (5bar) |
| Maximum Transmenbrane Pressure | 20 psig (1.4 bar) |
| Maximum Backwash Transmenbrane Pressure | 20 psig (1.4 bar) |
| Instantaneous Chlorine Tolerence | 100 ppm |
| Instantaneous Hydrogen Peroxide Tolerence | 200 ppm |
| Maximum Chlorine Exposure | 100,000 ppm-hrs |
| Maximum Instantaneous Feed Turbidity | 200 NTU |
| Maximum Operating Temperature | 104ºF (40ºC) |
| pH Operating Range | 4.0 - 10.0 |
| Cleaning pH Range | 1.5 - 13.0 |
| Operating Mode | Inside to Outside filtration Direct Flow or crossflow mode |
HYDRAcap 80 – 80″
| Configuration | Capillary Ultrafiltration Module |
| Membrane Polymer | Hydrophilic Polyethersulphone |
| Typical Filtrate Flux Range | 35 - 85 gfd (59 - 145 l/m2/h) |
| Maximum Applied Feed Pressure | 73 psig (5bar) |
| Maximum Transmenbrane Pressure | 20 psig (1.4 bar) |
| Maximum Backwash Transmenbrane Pressure | 20 psig (1.4 bar) |
| Instantaneous Chlorine Tolerence | 100 ppm |
| Instantaneous Hydrogen Peroxide Tolerence | 200 ppm |
| Maximum Chlorine Exposure | 100,000 ppm-hrs |
| Maximum Instantaneous Feed Turbidity | 100 NTU |
| Maximum Operating Temperature | 104ºF (40ºC) |
| pH Operating Range | 4.0 - 10.0 |
| Cleaning pH Range | 1.5 - 13.0 |
| Operating Mode | Inside to Outside filtration Direct Flow or crossflow mode |
HYDRAcap MAX 80 – 80″
| Configuration | Capillary Microfiltration Module |
| Membrane Polymer | PVDF |
| Typical Filtrate Flux Range | 20 - 65 gfd (34 - 110 l/m2/h) |
| Maximum Applied Feed Pressure | 73 psig (5bar) |
| Maximum Transmenbrane Pressure | 30 psig (2.0 bar) |
| Maximum Backwash Transmenbrane Pressure | |
| Instantaneous Chlorine Tolerence | 5000 ppm |
| Instantaneous Hydrogen Peroxide Tolerence | |
| Maximum Chlorine Exposure | 750,000 ppm-hrs |
| Maximum Instantaneous Feed Turbidity | 300 NTU |
| Maximum Operating Temperature | 104ºF (40ºC) |
| pH Operating Range | 4.0 - 10.0 |
| Cleaning pH Range | 1.0 - 13.0 |
| Operating Mode | Inside to Outside filtration Direct Flow or crossflow mode |
