| Technical
Data |
|
50 W |
100 W |
250 W |
400 W |
| Permeate flow
rate |
l/h |
50 |
100 |
250 |
400 |
| min. salt rejection |
% |
97 |
97 |
97 |
97 |
| recovery |
% |
75 |
75 |
75 |
75 |
| operating pressure |
bar |
14.0 |
12.0 |
11.0 |
10.0 |
| voltage |
V/Hz |
230 / 50 |
230 / 50 |
230 / 50 |
230 / 50 |
| membrane element/num. |
|
2540 / 1 |
2540 / 2 |
4040 / 1 |
4040 / 2 |
| motor power |
kW |
0.3 |
0.55 |
0.55 |
0.55 |
| pre-fusing |
A |
16 |
16 |
16 |
16 |
| feedwater connection |
DN |
20 |
20 |
20 |
20 |
| permeate/concentrate
connections |
DN |
10 |
10 |
10 |
10 |
| conductivity
range |
µS/cm |
1 – 99 |
1 – 99 |
1 – 99 |
1 – 99 |
| min./max. feedwater
pressure |
bar |
2 / 6 |
2 / 6 |
2 / 6 |
2 / 6 |
| min./max. feedwater
temperature |
°C |
5 / 35 |
5 / 35 |
5 / 35 |
5 / 35 |
| max. ambient
temperature |
°C |
40 |
40 |
40 |
40 |
| pH |
|
3 – 11 |
3 - 11 |
3 – 11 |
3 – 11 |
| height |
mm |
1,310 |
1,310 |
1,310 |
1,310 |
| width |
mm |
640 |
640 |
660 |
660 |
| depth |
mm |
300 |
300 |
300 |
315 |
| weight approx |
kg |
46 |
46 |
56 |
71 |
| Code no. |
|
380461 |
381011 |
381021 |
381031 |
| |
|
Buy Now |
Buy Now |
Buy Now |
Buy Now |
|
Wall mounting unit for desalination of softened
drinking water according to German drinking
water regulations (free chlorine not detectable),
operating on the principle of reverse osmosis.
Drinking water can also be desalinated with-out
pretreatment. However, in this case the recovery
rate is reduced. The decisive factor is the
water analysis.
Unit design
Stainless steel base frame with hinged plastic
front panel housing the instruments and controls.
Special inlet filter with 5 µm filter
cartridge, high pressure pump, rotary-vane
type, high performance wound module(s) with
PA/PS composite membranes in GRP pressure
vessel(s) with inliner.
Valves and instruments including solenoid
inlet valve, feedwater pressure switch, permeate
and concentrate flow meter, vibration-resistant
pressure gauges for pump and concentrate pressure,
stainless steel valves for adjustment of permeate
and concentrate flow rate.
Microprocessor control system as described
below, connecting cable (3 m) with 16 A –
6 h CEE three-pole plug.
Unit completely wired and pre-assembled and
ready for installation. Electrical equipment
in accordance with VDE 0100 part 600, VDE
113 part 1.
RO 500 microprocessor control system for
fully automated monitoring and control of
the reverse osmosis unit with two-digit alphanumeric
display of permeate conductivity, forced stop
and full tank, malfunction signals: low pressure,
hard water and high conductivity, LEDs for
operation and disinfection, inputs (low voltage)
for level control with 1 or 2 float switches,
hardness monitoring unit (the RO 500 controller
includes control functions for the limitron
hardness monitoring unit), shut-downs by external
signal (forced stop, regeneration), outputs
for softening unit (230 V/50 Hz) and DDC (collective
malfunction signal on floating changeover
contact).
Programming options for the following values
(preadjusted/limits)
- conductivity alarm 50/1-99 µS/cm
- conductivity prewarning 40/1-99 µS/cm
- conductivity alarm delay 5/1-250 min.
- interval for intermittent rinse when tank
full 24/1-250 h
- duration of rinse when tank full 15/1-99
min.
- duration of concentrate displacement 60/1-250
sec.
Programming by manufacturer only.
The units are designed for a maximum TDS
of 1,000 mg/l, a water temperature of 15°C
and a maximum fouling index of 3. Under these
conditions, the units still reach design permeate
flow after 3 years of operation. The permeate
recovery depends on the raw water quality
and the type of pretreatment.
Optional equipment
Hardness Monitoring Unit limitron _"
for constant monitoring of the feedwater hardness,
completely integrated in the reverse osmosis
unit. Code-no. 370038
|