Reverse Osmosis - AS Range 10,000 to 20,000 l/ph

Technical Data   UO 10000 UO 12000 UO 15000 UO 18000 UO 20000
Permeate flow rate l/h 10,000 12,000 15,000 18,000 2,000
min. salt rejection % 97 97 97 97 97
recovery % 75 75 75 75 75
operating pressure bar 12.0 11.5 12.0 12.0 11.5
membrane element / number   8040 / 9 8040 / 10 8040 / 12 8040 / 15 8040 / 17
voltage V/Hz 3 x 400 / 50 3 x 400 / 50 3 x 400 / 50 3 x 400 / 50 3 x 400 / 50
motor power kW 11 11 11 15 15
pre-fusing A 25 25 25 32 32
feedwater connection DN 50 50 65 65 65
permeate/concentrate connections DN 50 / 32 50 / 50 65 / 50 65 / 50 65 / 50
connection dosing point R _“ _“ _“ _“ _“
conductivity range   2 – 200 2 – 200 2 – 200 2 – 200 2 – 200
min./max. feedwater pressure bar 2 / 6 2 / 6 2 / 6 2 / 6 2 / 6
min./max. feedwater temperature °C 5 / 35 5 / 35 5 / 35 5 / 35 5 / 35
max. ambient temperature °C 40 40 40 40 40
pH   3 – 11 3 - 11 3 – 11 3 – 11 3 – 11
height mm 1,900 1,900 1,900 1,900 2,200
width mm 3,900 4,900 4,900 5,900 4,900
depth mm 800 800 800 800 800
weight approx kg 900 1,000 1,100 1,300 1,500
Code no.   381590 381600 381610 381620 381630
    Buy Now Buy Now Buy Now Buy Now Buy Now

Stand-type unit for desalination of hardness stabilized drinking water according to UK drinking water regulations (free chlorine not detectable), operating on the principle of reverse osmosis.

Unit design

Stainless steel main frame housing the instruments and controls.

Special inlet filter with 5 µm-filter cartridge, high pressure pump low noise, multi-stage centrifugal type, low energy spirally wound modules with energy-efficient PA/PS composite membranes in GRP vessels with inliner.
Valves such as sampling valves for feed water and permeate (for each pressure vessel), inlet dia-phragm valve, valves made of stainless steel to regulate the flow rate of permeate, concentrate and concentrate recirculation.
Pressure gauges for inlet and outlet pressure pre-filter, pump pressure, operating pressure and concentrate pressure, pressure switch for monitoring the feed water pressure.

Flow meters for permeate, concentrate and concentrate recirculation flow rate.

Conductivity measurement permeate, temperature compensated, measuring range 2-200 µS/cm.

Connection set for cleaning device, T-piece for injection point, concentrate flushing device.

Control cabinet with lockable main switch, electrical switchgear for control of the high-pressure pump and antiscalant dosing unit.

RO 1000 microprocessor control system for fully automated monitoring and control of the sys-tem with two line text display (16 characters per line) for display of operational status, permeate conductivity, temperature, operating hours, password-protected programming of the operating se-quences and parameters as described below. Operators functions with password on different levels, low pressure shut down, conductivity limit fault and conductivity limit pre-alarm, malfunction dis-plays for low pressure, hard water/motor overload, high conductivity pre-alarm, power supply malfunction.

Programming options for the following operating status with selectable duration:

  • discard of permeate, subject to conductivity, with time limit
  • discard of permeate, subject to time
  • shut-down at high conductivity
  • failure acknowledgement with or without password
  • operators functions via password on different levels
  • low pressure shut-down 0-99 sec.
  • conductivity limit delay 0-99 min.
  • conductivity limit fault 2-200 µS/cm
  • conductivity limit prealarm 2-200 µS/cm
  • interval for intermittent rinse when "tank full" 0-99 h
  • duration of rinse when "tank full" 0-99 min.
  • duration of concentrate displacement 0-99 min.
  • duration of concentrate rinse 0-99 min.
  • duration of permeate discard accord. to conductivity 1-99 min.
  • range of permeate conductivity 2-200 µS/cm
  • pump delay 0-9.9 sec.
  • language German/English/French/Italian
  • individual test of all inputs or outputs with LCD (diagnostics)

Additional connections possible: Inputs (low voltage) for level control with 1 or 2 float switches, hardness monitoring unit (the RO 1000 control system includes control functions for the limitron hardness monitoring unit), shut-down by external signal (forced stop, regeneration), Outputs for softener (230 V/50 Hz), 2 solenoid valves for concentrate rinse, permeate discard and -recycling, and DDC (collective malfunction signal on volt-free changeover contact).

Unit completely wired, pre-assembled and ready for installation. Electrical equipment in accordance with VDE 0100 part 600, VDE 113 part 1. Compressed air (oil-free) 4-6 bar required.

The units are designed for a maximum TDS of 1,000 mg/l, a water temperature of 15°C, a maximum colloidal index of 3 and free permeate outlet. Under these conditions, the units still reach design permeate flow after three years of operation. The permeate recovery depends on the raw water quality and the type of pre-treatment.

Optional Equipment
Surcharge for microprocessor control RO 5000 Code no. 382140

Permeate recirculation PR
Code no. 382373 for RO units UO 10000
Code no. 382092 for RO units UO 12000-15000
Code no. 382093 for RO units UO 18000-20000

 

back

Industrial Water Equipment Ltd
4 Causeway Lane, Matlock
Derbyshire, DE4 3AR
TEL: +44 (0)1629 55839
FAX: +44 (0)1629 501055

2nd Floor, 13 Upper Baggot Street, Dublin 4, Ireland
TEL: + 00 353 14428670

info@industrialwaterequipment.co.uk

24Hr Helpline - Emergency
Number : 07775 661688

 

payment logos

| Quick Shop | Sitemap | Terms & Conditions of Sale | Returned Goods Policy | Payment Option| Account Application

copyright notice

 

Technical

water softner tech libraryNeed further Technical information on reverse osmosis?

View our Reverse Osmosis Tech Library

Related Products

Pretreatment
Reverse Osmosis Polishing Units
Water Testing Equipment
Membrane Housings
Controllers
Reverse Osmosis Cleaning Chemicals
Reverse Osmosis Membranes
Cartridge Filters
Equipment Servicing
Maintenance
Installation Services

Articles

water softener articlesBrowse our reverse osmosis articles for the latest information

Click Here

 

Blog Posts

water industry blog newsVist our latest Industrial Water Equipment blog posts for the most up to date information on the water treatment industry.

Videos

water softener videosReverse Osmosis related videos - view the latest information online.

Click Here

Drinking Water RO Range

domestic reverse osmosis unitsIWE's brand new range of compact drinking water reverse osmosis units.

reverseosmosiswater.co.uk