LSE Water Chillers Series
LSE Series water chillers - heat pumps preference will be dependent upon the actual 100 % load of the plant, the effective thermal load of the air conditioning plant is operating at 90% of the time, 60% less compared to the nominal load.
twelve models make up the LSE range of water chillers, with cooling capability from 360 to 920 kW (620 kW with regard to the heat pump) and employ scroll compressors with either two or four refrigerant circuits.
High performance on partial loads The actual quantity of compressors is dependent on the size, ranging from 2 to 3 for every refrigerant circuit, multiplying the partial steps. The higher amount of partial loads allows the water chiller to adapt it's capability towards the effective requirements of the plant, paying particular requirements to the partial loads compared to the conventional screw compressors. The microprocessor management distributes automatically and seperates the operating procedures of the compressors, thus increasing their operating life. On the partial load operations, the compressors perform with extra-large exchange surface utilising much more effective thermodynamic cycles, thanks to the employment of standard electronic expansion valves fitted to all the LSE range of water chillers.
LSE Water Chiller range options
Cooling only
Free-Cooling
Heat pump, up to 620 kW.
Hydraulic Options
Built in Hydronic kits
Single pump, standard head or uprated
Double pump solution : standard head or up rated
Optimised working limits
Electronic expansion valve
Dedicated air section for Smart Defrost logic
Double reversing cycle extends the working field of the heat pump unit , from -10 °C to -15°C
Interconnectivity
The implement of sophisticated microprocessors as standard enables:
LAN network recognition
Ergo Network
GSM kit for data reading as well as establishing via a cell phone.
Internet kit for data reading and setting from remote PC through access to the IP address of the unit or of the unit network.
| Technical Specification |
| LSE |
360 |
400 |
440 |
470 |
540 |
580 |
| Cooling Capacity kW |
355,5 |
394,4 |
439,0 |
468,2 |
539,1 |
586,1 |
| Power Input kW |
132,4 |
149,4 |
163,6 |
176,4 |
189,6 |
210,8 |
| Heating Capacity kW |
406,4 |
451,9 |
482,0 |
509,3 |
602,0 |
639,1 |
| Power Input kW |
127,7 |
142,4 |
157,5 |
169,0 |
193,5 |
208,8 |
| |
Buy Now |
Buy Now |
Buy Now |
Buy Now |
Buy Now |
Buy Now |
| LSE |
620 |
700 |
780 |
860 |
920 |
|
| Cooling Capacity kW |
622,1 |
705 |
784 |
861 |
918 |
|
| Power Input kW |
229,2 |
240 |
293 |
322 |
349 |
|
| EER |
675,0 |
2,94 |
2,68 |
2,67 |
2,63 |
|
| ESEER |
224,2 |
4,18 |
3,87 |
3,78 |
3,73 |
|
| |