Laboratory Electrodes |
Laboratory - Intelligent
Pages 1 - 2 - 3
| HI1618 |
HI3619 |
 |
 |
| Reference |
Reference |
| Single, Ag/AgCl |
Single, Ag/AgCl |
| Junction |
Junction |
| Cloth |
Ceramic, single |
| Electrolyte |
Electrolyte |
| Gel |
KCl 3.5 + AgCl |
| Max Pressure |
Max Pressure |
| 3 bar |
0.1 bar |
| Range |
Range |
| pH: 0 to 13 T: 0 to 80°C
(32 to 176°F) |
ORP T: -5 to 80°C (23
to 176°F) |
| Tip Shape |
Tip Shape |
| Spheric (dia: 5 mm) |
Platinum pin |
| Temperature Sensor |
Temperature Sensor |
| Yes |
No |
| Amplifier |
Amplifier |
| Yes |
Yes |
| Body Material |
Body Material |
| Ultem® |
Glass |
| Cable** |
Cable** |
| 7-pole; 1 m (3.3’) |
7-pole; 1 m (3.3’) |
| Recommended Use |
Recommended Use |
| Field applications |
Laboratory general use, disinfections |
| Click
Here for more information &
to buy. |
Click
Here for more information &
to buy. |
|
Laboratory - Special ORP
| HI3618 |
HI3620 |
HI4619 |
 |
 |
 |
| Reference |
Reference |
Reference |
| Single, Ag/AgCl |
Single, Ag/AgCl |
Single, Ag/AgCl |
| Junction |
Junction |
Junction |
| Ceramic, single |
Ceramic, single |
Ceramic, single |
| Electrolyte |
Electrolyte |
Electrolyte |
| KCl 3.5M + AgCl |
Gel |
Gel |
| Max Pressure |
Max Pressure |
Max Pressure |
| 0.1 bar |
2 bar |
2 bar |
| Range |
Range |
Range |
| ORP T: -5 to 100°C (23 to
212°) |
ORP T: 0 to 80°C (32 to
176°F) |
ORP T: -5 to 100°C (23 to
212°) |
| Tip Shape |
Tip Shape |
Tip Shape |
| Platinum pin |
Platinum pin |
Gold pin |
| Temperature Sensor |
Temperature Sensor |
Temperature Sensor |
| Yes |
No |
Yes |
| Amplifier |
Amplifier |
Amplifier |
| Yes |
Yes |
Yes |
| Body Material |
Body Material |
Body Material |
| Glass |
Ultem® |
Glass |
| Cable** |
Cable** |
Cable** |
| 5-pole; 1 m (3.3’) |
7-pole; 1 m (3.3’) |
5-pole; 1 m (3.3’) |
| Recommended Use |
Recommended Use |
Recommended Use |
| Laboratory |
Field applications, swimming
pools |
Strong oxidants, disinfections
with ozone |
| Click Here for more information
& to buy. |
Click
Here for more information &
to buy. |
Click
Here for more information &
to buy. |
|
Laboratory - Electrodes
with Temperature Sensor
| HI1217 |
HI1610 |
HI1611 |
 |
 |
 |
| Reference |
Reference |
Reference |
| Single, Ag/AgCl |
Single, Ag/AgCl |
Single, Ag/AgCl |
| Junction |
Junction |
Junction |
| Ceramic, single |
Ceramic, single |
Ceramic, triple |
| Electrolyte |
Electrolyte |
Electrolyte |
| Gel |
KCl 3.5M + AgCl |
Gel |
| Max Pressure |
Max Pressure |
Max Pressure |
| 2 bar |
0.1 bar |
2 bar |
| Range |
Range |
Range |
| pH: 0 to 13 T: 0 to 80°C
(32 to 176°F) |
pH: 0 to 13 T: -5 to 100°C
(23 to 212°F) |
pH: 0 to 14 T: 0 to 100°C
(32 to 212°F) |
| Tip Shape |
Tip Shape |
Tip Shape |
| Spheric (dia: 5.0 mm) |
Spheric (dia: 9.5 mm) |
Spheric (dia: 9.5 mm) |
| Temperature Sensor |
Temperature Sensor |
Temperature Sensor |
| Yes |
Yes |
Yes |
| Amplifier |
Amplifier |
Amplifier |
| Yes |
Yes |
Yes |
| Body Material |
Body Material |
Body Material |
| Ultem® |
Glass |
Glass |
| Cable** |
Cable** |
Cable** |
| 5-pole; 1 m (3.3’) |
5-pole; 1 m (3.3’) |
5-pole; 1 m (3.3’) |
| Recommended Use |
Recommended Use |
Recommended Use |
| General purpose |
Laboratory general use |
Continuous monitoring |
| Click Here for more information
& to buy. |
Click Here for more information
& to buy. |
Click
Here for more information &
to buy. |
|
Laboratory
- Electrodes with Temperature Sensor
| HI1612 |
FC211 |
 |
 |
| Reference |
Reference |
| Single, Ag/AgCl |
Single, Ag/AgCl |
| Junction |
Junction |
| Ceramic, triple |
Open |
| Electrolyte |
Electrolyte |
| KCl 3.5M + AgCl |
Viscolene |
| Max Pressure |
Max Pressure |
| 0.1 bar |
0.1 bar |
| Range |
Range |
| pH: 0 to 12 T: -5 to 100°C
(23 to 212°F) |
pH: 0 to 12 T: 0 to 50°C
(32 to 122°F) |
| Tip Shape |
Tip Shape |
| Conic (12 x 12 mm) |
Conic (12 x 12 mm) |
| Temperature Sensor |
Temperature Sensor |
| Yes |
Yes |
| Amplifier |
Amplifier |
| Yes |
Yes |
| Body Material |
Body Material |
| Glass |
Glass |
| Cable** |
Cable** |
| 5-pole; 1 m (3.3’) |
5-pole; 1 m (3.3’) |
| Recommended Use |
Recommended Use |
| Emulsions, semi solid samples |
Milk, yogurt, cream |
| Click Here for more information
& to buy. |
Click
Here for more information &
to buy. |
Pages 1 - 2 - 3
|
|
 |
Industrial Water Equipment Ltd
4 Causeway Lane, Matlock
Derbyshire, DE4 3AR
TEL: +44 (0)1629 55839
FAX: +44 (0)1629 501055
2nd Floor, 13 Upper Baggot Street, Dublin
4, Ireland
TEL: + 00 353 14428670
info@industrialwaterequipment.co.uk
24Hr
Helpline - Emergency
Number : 07775 661688 |

| Quick
Shop | Sitemap | Terms
& Conditions of Sale | Returned
Goods Policy | Payment
Option| Account Application

|
|
|
| Click Here
for Comparison Chart |
| Technical |
Looking for technical information on water treatment? IWE's tech library may be able to help - we are compiling a fantastic library full of information on water treatment and product FAQ's. Tech Library |
| Related Products |
|
| Articles |
All the latest articles from the world of water treatment.
Click Here |
| Videos |
Water treatment related videos - view the latest information online.
Click Here |
| Blog Posts |
Visit our latest Industrial Water Equipment blog posts for the most up to date information on the water treatment industry.
|
| Price Guarantee |
IWE Guarantee to beat any like for like quote for water treatment and parts by 10% and any like for like service / maintenance contract by 20%
|
|
|