HI1618 HI3619
HI1618 HI3619
Reference Reference
Single, Ag/AgCl Single, Ag/AgCl
Junction Junction
Cloth Ceramic, single
Electrolyte Electrolyte
Gel KCl 3.5 + AgCl
Max Pressure Max Pressure
3 bar 0.1 bar
Range Range
pH: 0 to 13 T: 0 to 80°C (32 to 176°F) ORP T: -5 to 80°C (23 to 176°F)
Tip Shape Tip Shape
Spheric (dia: 5 mm) Platinum pin
Temperature Sensor Temperature Sensor
Yes No
Amplifier Amplifier
Yes Yes
Body Material Body Material
Ultem® Glass
Cable** Cable**
7-pole; 1 m (3.3’) 7-pole; 1 m (3.3’)
Recommended Use Recommended Use
Field applications Laboratory general use, disinfections
Click Here for more information & to buy. Click Here for more information & to buy.

Laboratory - Special ORP

HI3618 HI3620 HI4619
HI3618 HI3620 HI4619
Reference Reference Reference
Single, Ag/AgCl Single, Ag/AgCl Single, Ag/AgCl
Junction Junction Junction
Ceramic, single Ceramic, single Ceramic, single
Electrolyte Electrolyte Electrolyte
KCl 3.5M + AgCl Gel Gel
Max Pressure Max Pressure Max Pressure
0.1 bar 2 bar 2 bar
Range Range Range
ORP T: -5 to 100°C (23 to 212°) ORP T: 0 to 80°C (32 to 176°F) ORP T: -5 to 100°C (23 to 212°)
Tip Shape Tip Shape Tip Shape
Platinum pin Platinum pin Gold pin
Temperature Sensor Temperature Sensor Temperature Sensor
Yes No Yes
Amplifier Amplifier Amplifier
Yes Yes Yes
Body Material Body Material Body Material
Glass Ultem® Glass
Cable** Cable** Cable**
5-pole; 1 m (3.3’) 7-pole; 1 m (3.3’) 5-pole; 1 m (3.3’)
Recommended Use Recommended Use Recommended Use
Laboratory Field applications, swimming pools Strong oxidants, disinfections with ozone
Click Here for more information & to buy. Click Here for more information & to buy. Click Here for more information & to buy.

Laboratory - Electrodes with Temperature Sensor

HI1217 HI1610 HI1611
HI1217 HI1610 HI1611
Reference Reference Reference
Single, Ag/AgCl Single, Ag/AgCl Single, Ag/AgCl
Junction Junction Junction
Ceramic, single Ceramic, single Ceramic, triple
Electrolyte Electrolyte Electrolyte
Gel KCl 3.5M + AgCl Gel
Max Pressure Max Pressure Max Pressure
2 bar 0.1 bar 2 bar
Range Range Range
pH: 0 to 13 T: 0 to 80°C (32 to 176°F) pH: 0 to 13 T: -5 to 100°C (23 to 212°F) pH: 0 to 14 T: 0 to 100°C (32 to 212°F)
Tip Shape Tip Shape Tip Shape
Spheric (dia: 5.0 mm) Spheric (dia: 9.5 mm) Spheric (dia: 9.5 mm)
Temperature Sensor Temperature Sensor Temperature Sensor
Yes Yes Yes
Amplifier Amplifier Amplifier
Yes Yes Yes
Body Material Body Material Body Material
Ultem® Glass Glass
Cable** Cable** Cable**
5-pole; 1 m (3.3’) 5-pole; 1 m (3.3’) 5-pole; 1 m (3.3’)
Recommended Use Recommended Use Recommended Use
General purpose Laboratory general use Continuous monitoring
Click Here for more information & to buy. Click Here for more information & to buy. Click Here for more information & to buy.

 

 

Laboratory - Electrodes with Temperature Sensor

HI1612 FC211
HI1612 FC211
Reference Reference
Single, Ag/AgCl Single, Ag/AgCl
Junction Junction
Ceramic, triple Open
Electrolyte Electrolyte
KCl 3.5M + AgCl Viscolene
Max Pressure Max Pressure
0.1 bar 0.1 bar
Range Range
pH: 0 to 12 T: -5 to 100°C (23 to 212°F) pH: 0 to 12 T: 0 to 50°C (32 to 122°F)
Tip Shape Tip Shape
Conic (12 x 12 mm) Conic (12 x 12 mm)
Temperature Sensor Temperature Sensor
Yes Yes
Amplifier Amplifier
Yes Yes
Body Material Body Material
Glass Glass
Cable** Cable**
5-pole; 1 m (3.3’) 5-pole; 1 m (3.3’)
Recommended Use Recommended Use
Emulsions, semi solid samples Milk, yogurt, cream
Click Here for more information & to buy. Click Here for more information & to buy.

Pages 1 - 2 - 3

back

Industrial Water Equipment Ltd
4 Causeway Lane, Matlock
Derbyshire, DE4 3AR
TEL: +44 (0)1629 55839
FAX: +44 (0)1629 501055

2nd Floor, 13 Upper Baggot Street, Dublin 4, Ireland
TEL: + 00 353 14428670

info@industrialwaterequipment.co.uk

24Hr Helpline - Emergency
Number : 07775 661688

 

payment logos

| Quick Shop | Sitemap | Terms & Conditions of Sale | Returned Goods Policy | Payment Option| Account Application

copyright notice

Click Here for Comparison Chart
Technical

Looking for water softner tech librarytechnical information on water treatment? IWE's tech library may be able to help - we are compiling a fantastic library full of information on water treatment and product FAQ's. Tech Library

Related Products



Articles

water articlesAll the latest articles from the world of water treatment.

Click Here

Videos

videosWater treatment related videos - view the latest information online.

Click Here

Blog Posts

water industry blog newsVisit our latest Industrial Water Equipment blog posts for the most up to date information on the water treatment industry.

Price Guarantee

price promiseIWE Guarantee to beat any like for like quote for water treatment and parts by 10% and any like for like service / maintenance contract by 20%