Laboratory - Combination

Pages 1 - 2 - 3

HI104X HI105X HI1083
HI104X HI105X HI1083
Reference Reference Reference
Double, Ag/AgCl Single, Ag/AgCl Single, Ag/AgCl
Junction Junction Junction
Ceramic, single Ceramic, triple Open
Electrolyte Electrolyte Electrolyte
KCl 3.5M KCl 3.5M + AgCl Viscolene
Max Pressure Max Pressure Max Pressure
0.1 bar 0.1 bar 0.1 bar
Range Range Range
pH: 0 to 14 T: 0 to 100°C (32 to 212°F) pH: 0 to 12 T: -5 to 100°C (23 to 212°F) pH: 0 to 13 T: 0 to 50°C (32 to 122°F)
Tip Shape Tip Shape Tip Shape
Spheric (dia: 9.5 mm) Conic (12 x 12 mm) Spheric (dia: 3 mm)
Temperature Sensor Temperature Sensor Temperature Sensor
No No No
Amplifier Amplifier Amplifier
No No No
Body Material Body Material Body Material
Glass Glass Glass
Cable** Cable** Cable**
Coaxial; 1 m (3.3’) Coaxial; 1 m (3.3’) Coaxial; 1 m (3.3’)
Recommended Use Recommended Use Recommended Use
Hydrocarbon, paints, solvents, sea water, strong acid and base, high conductivity samples, Tris buffer Fats and creams, soil samples, potable water, semi solid products, low conductivity solutions, emulsions Biotechnology, samples < 100 ul
Click Here for more information & to buy. Click Here for more information & to buy. Click Here for more information & to buy.

 

Laboratory - Combination

HI1093 HI11X1 HI1135
HI1093 HI11X1 HI1135
Reference Reference Reference
Single, Ag/AgCl Single, Ag/AgCl Double, Ag/AgCl
Junction Junction Junction
Open Ceramic, single Ceramic, double
Electrolyte Electrolyte Electrolyte
Viscolene KCl 3.5M + AgCl KCl 3.5M
Max Pressure Max Pressure Max Pressure
0.1 bar 0.1 bar 3 bar with back pressure
Range Range Range
pH: 0 to 13 T: -5 to 50°C (23 to 122°F) pH: 0 to 13 T: -5 to 100°C (23 to 212°F) pH: 0 to 14 T: -5 to 100°C (23 to 212°F)
Tip Shape Tip Shape Tip Shape
Spheric (dia: 3 mm) Spheric (dia: 9.5 mm) Spheric (dia: 9.5 mm)
Temperature Sensor Temperature Sensor Temperature Sensor
No No No
Amplifier Amplifier Amplifier
No No No
Body Material Body Material Body Material
Glass Glass Glass
Cable** Cable** Cable**
Coaxial; 1 m (3.3’) Coaxial; 1 m (3.3’) Coaxial; 1 m (3.3’)
Recommended Use Recommended Use Recommended Use
NMR tubes Laboratory general purpose, beer Continuous monitoring with remote filling
Click Here for more information & to buy. Click Here for more information & to buy. Click Here for more information & to buy.

 

Laboratory - Combination

HI1143 HI1144 HI12X0
HI1143 HI1144 HI12X0
Reference Reference Reference
Double, Ag/AgCl Single, Hg/Hg2Cl2 Double, Ag/AgCl
Junction Junction Junction
Ceramic, single Ceramic Ceramic, single
Electrolyte Electrolyte Electrolyte
KCl 3.5M KCl 3.5M Gel
Max Pressure Max Pressure Max Pressure
0.1 bar 0.1 bar 2 bar
Range Range Range
pH: 0 to 10 T: -5 to 60°C (23 to 140°F) pH: 0 to 14 T: 0 to 60°C (32 to 140°F) pH: 0 to 13 T: 0 to 80°C (32 to 176°F)
Tip Shape Tip Shape Tip Shape
Spheric (dia: 9.5 mm) Spheric (dia: 9.5 mm) Spheric (dia: 7.5 mm)
Temperature Sensor Temperature Sensor Temperature Sensor
No No No
Amplifier Amplifier Amplifier
No No No
Body Material Body Material Body Material
Glass Glass Glass
Cable** Cable** Cable**
Coaxial; 1 m (3.3’) Coaxial; 1 m (3.3’) Coaxial; 1 m (3.3’)
Recommended Use Recommended Use Recommended Use
Samples with fluoride (max 2 g/L @ pH 2 and
temperature < 60°C)
Tris buffer Field applications
Click Here for more information & to buy. Click Here for more information & to buy. Click Here for more information & to buy.

Pages 1 - 2 - 3

back

Industrial Water Equipment Ltd
4 Causeway Lane, Matlock
Derbyshire, DE4 3AR
TEL: +44 (0)1629 55839
FAX: +44 (0)1629 501055

2nd Floor, 13 Upper Baggot Street, Dublin 4, Ireland
TEL: + 00 353 14428670

info@industrialwaterequipment.co.uk

24Hr Helpline - Emergency
Number : 07775 661688

 

payment logos

| Quick Shop | Sitemap | Terms & Conditions of Sale | Returned Goods Policy | Payment Option| Account Application

copyright notice

Click Here for Comparison Chart
Technical

Looking for water softner tech librarytechnical information on water treatment? IWE's tech library may be able to help - we are compiling a fantastic library full of information on water treatment and product FAQ's. Tech Library

Related Products



Articles

water articlesAll the latest articles from the world of water treatment.

Click Here

Videos

videosWater treatment related videos - view the latest information online.

Click Here

Blog Posts

water industry blog newsVisit our latest Industrial Water Equipment blog posts for the most up to date information on the water treatment industry.

Price Guarantee

price promiseIWE Guarantee to beat any like for like quote for water treatment and parts by 10% and any like for like service / maintenance contract by 20%